| Agency | Form: (05) 2512978 11/17/2010 | THIS IS FORM 5 FOR ORIGINAL HOLE. DHS |
| Engineer | Form: (02) 2512975 12/07/2010 | CONDITIONS OF APPROVAL FOR THIS SIDETRACK ARE THE SAME AS THOSE ON THE PERMIT FOR THE ORIGINAL HOLE. DOCUMENT # 1527630
|
| Data Entry | Form: (05) 2331899 03/20/2012 | ADDITIONAL FORMATIONS WITH UNRECOGNIZED NAMES W/ TOP MEASURED DEPTHS:
MESAVERDE/WILLIAMS FORK 4139'
PRICE COAL 5038'
TOP GAS 6110'
ALSO TWO SETS OF FIGURES GIVEN FOR CONDUCTOR CASING, 2ND SET:
24" 13 3/8" 125' DEPTH 150 SX CMT CMT TOP=0 CMT BTM= 125' CALC.
|
| Engineer | Form: (04) 400411678 06/03/2013 | monitor bradenhead pressure (BHP) and pressure in other annulus during completion operations. notify COGCC if BHP reaches 150 psi, and stop completion operations should a high BHP occur during. |
| Engineer | Form: (04) 402209483 10/30/2019 | 1) Operator shall comply with the Notice to Operators Drilling Wells in the Buzzard, Mamm Creek, and Rulison fields, Garfield County and Mesa County – Procedures and Submittal Requirements for Compliance with COGCC Order Nos. 1-107, 139-56, 191-22, and 369-2 (“Bradenhead NTO”), dated July 8, 2010.
2) At least once a year shut in bradenhead for 7 days and perform a bradenhead test if pressure builds to 150 psi. Report results on operator’s annual spreadsheet and on a Form 17 if bradenhead test was performed, as specified in the Bradenhead NTO.
3) Comply with any CDPHE, Air Pollution Control Division rules or requirements for all atmospheric discharges.
4) Any liquids blown down are to be collected, stored, handled, and treated or disposed as E&P waste per COGCC’s 900 series rules.
5) At least one check valve is required for annular spaces that are tied to sales. Maintain equipment for pressure regulation and check valves in good working order.
|