WELL05-005-07197Tebo 3
1H
CRESTONE PEAK RESOURCES OPERATING LLC
10633
SI
3/1/2025
DJ HORIZONTAL NIOBRARA
16950
ARAPAHOE  005
NENE 3 5s64W 6
430346View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02 )
400312520
9/18/2012
1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU. 2) Comply with Rule 317.i and provide cement coverage from end of 7” casing to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 3) Comply with Rule 321. Run and submit Directional Survey from TD to base of surface casing. Ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
EngineerForm: (02 )
400319966
9/18/2012
1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU.
EngineerForm: (04 )
402575700
2/24/2021
All gas volumes are to be metered and combusted with a device with a 98% design efficiency for hydrocarbon destruction. The flared volumes are to be reported in the Form 7, Monthly Report of Operations.
EngineerForm: (04 )
402575700
2/24/2021
The approved productivity test is not to exceed 60 calendar days and the well is to be shut in if a gas capture plan or Sundry requesting to continue to produce without infrastructure has not been approved by that time.
EngineerForm: (04 )
402046980
10/8/2021
1) Flaring of natural gas shall comply with COGCC Rule 912. 2) Submit requests to flare annually to COGCC on Form 4 (Sundry Notice), which discusses timing to connect to sales line, plans to develop infrastructure, and justification for continued venting/flaring. Provide gas analysis including H2S with each Sundry Notice. 3) Report metered flaring volumes on Form 7, Operator??s Monthly Report of Operations. 4) The operator is required to obtain and maintain any required air permits from CDPHE. 5) The expectation for permanent flares controlling separators will be an enclosed combustion device with a 98% design destruction efficiency for hydrocarbons. 6) Notify the local emergency dispatch or the local governmental designee of natural gas flaring.
EngineerForm: (04 )
402719491
2/25/2022
Operator shall have an approved Gas Capture Plan or have sought and received a variance from the COGCC Commission for continued production without gas infrastructure, prior to January 15, 2022 or wells must be shut in by January 15, 2022.
EngineerForm: (04 )
402719491
2/25/2022
Gas volumes for productivity test not reported on Form7, amend reporting.
EngineerForm: (04 )
403368529
4/10/2023
If well is not producing by March 31, 2024, an official MIT will need to be done.
EngineerForm: (04 )
403368529
4/10/2023
Well has been designated Inactive as of 06/30/2021. Submit a Form 5B, Inactive Well Notice.
EngineerForm: (04 )
404005100
12/3/2024
1) Provide electronic Form 42 Notice of MIRU 2 business days ahead of operations. 2) Operator shall implement measures to control venting, to protect health and safety, and to ensure that vapors and odors from well operations do not constitute a nuisance or hazard to public welfare.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
PlanningForm: (04 )
404005100
12/3/2024
Lights: Operator will conduct operations during daylight hours only.
Odor mitigationForm: (04 )
404005100
12/3/2024
Nuisance odors are not anticipated for this Operation, however, will be monitored and treated, as necessary. Daily Operation summaries will document to ensure all BMP’s and COA’s are met.