Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-001-08190RANDALL
22-2
KP KAUFFMAN COMPANY INC
46290
PR
12/1/2025
KRAUTHEAD
47550
ADAMS  001
SENW 2 1S64W 6
320134View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
401677637
09/02/2018
NOTE: Changes in plugging procedure. CBL to be run prior to plugging to verify stage tool setting depth and existing coverage - submit to COGCC for verification of plugging orders. Additional plugs required. 1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) For 1240’ plug: pump plug and displace - tag plug – must be 1080’ or shallower. If surface casing plug is perforated at 650', pumped to surface and does not remain at surface, tag plug and assure there is cement on the inside and outside of 4-1/2" casing (if unable to pull). 3) Properly abandon flowlines as per Rule 1105. File electronic Form 42 once abandonment complete. Within 30 days of an operator completing abandonment requirements for an off-location flowline or crude oil transfer line the operator must submit a Flowline Report, Form 44.
 
COGIS - Best Management Practice Results
No records to display.