Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
LOCATION441005Pronghorn
D-28 Pad
BONANZA CREEK ENERGY OPERATING COMPANY LLC
8960
AC
1/1/2025
RIVERSIDE
73800
WELD  123
SWSW 28 5N61W 6
441005View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
OGLAForm: (02A)
400728893
01/07/2015
Operator shall provide notice to COGCC 48 hours prior to commencing construction of this Oil and Gas Location via Form 42. Operator Concurrence via email 01/08/2015
OGLAForm: (02A)
400728893
01/07/2015
Unnecessary or excessive flaring is prohibited. Operator shall direct all salable quantity gas to a sales line as soon as practicable or shut in and conserved. Operator Concurrence via email 01/08/2015
OGLAForm: (02A)
400728893
02/10/2015
If, in the event, the listed Production Facilities are removed from this Location, Operator shall submit a Form 4 Sundry updating the changes to the permitted facilities list at this Location.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
ConstructionForm: (02A )
400728893
3/4/2015
The following procedure describes BCEI standard construction practices for setting a partially buried pre-cast cement water vault and new tank battery construction. 1) The excavation will first be lined with 4” of clay or other low permeability soil. 2) A 30 mil liner will be installed on top of the low permeability soil. The 30 mil liner will be a contiguous liner which will underlay the entire tank battery. 3) The tank battery / water vault liner will be keyed into a galvanized steel containment ring installed surrounding the tank battery. 4) Sand bedding will be installed to protect the synthetic liner prior to placing equipment in the containment area.
ConstructionForm: (02A )
400728893
3/4/2015
Bonanza is working to consolidate its oil and gas facilities for the multiple benefits incurred and our plan is not to build excessive facilities on this location. Upon approval, Bonanza will be constructing a drilling pad which will have production going to the State Pronghorn CPF 41-32 Location ID# 438946. There will be some facility equipment on the Pronghorn D-28 pad, however it is the intention of Bonanza to minimize surface disturbance and excessive construction.
Drilling/Completion OperationsForm: (02A )
400728893
3/4/2015
BMP-Bonanza Creek Energy acknowledges and will comply with the “COGCC Policy On the Use of Modular Large Volume Tanks in Colorado” dated June 13, 2014.
ConstructionForm: (04 )
401623412
5/24/2018
Bonanza Creek Energy acknowledges and will comply with the “COGCC Policy On the Use of Modular Large Volume Tanks in Colorado” dated June 13, 2014.