COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
OGLAForm: (02A)
400705762
11/14/2014
Operator shall provide notice to COGCC 48 hours prior to commencing construction of this Oil and Gas Location via Form 42.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
PlanningForm: (02A )
400705762
12/5/2014
Multi-well Pads. It is a multi-well pad located in a manner which allows for resource extraction while maintaining the highest distances possible from the offsetting residential areas.
Traffic controlForm: (02A )
400705762
12/5/2014
Access roads. The access road will be constructed to accommodate local emergency vehicles. This road will be maintained for access at all times
General HousekeepingForm: (02A )
400705762
12/5/2014
Fencing requirements. A permanent fencing plan will be reviewed by the surface owner, & the applicant.
General HousekeepingForm: (02A )
400705762
12/5/2014
Removal of surface trash. All trash, debris and material not intrinsic to the operation of the oil and gas facility shall be removed and legally disposed of as is applicable
Material Handling and Spill PreventionForm: (02A )
400705762
12/5/2014
Load-lines. All load-lines shall be bull-plugged or capped
Material Handling and Spill PreventionForm: (02A )
400705762
12/5/2014
8. Material Handling and Spill Prevention
Noise mitigationForm: (02A )
400705762
12/5/2014
Lighting abatement measures shall be implemented, including the installation lighting shield devices on all of the more conspicuous lights, low density sodium lighting where practicable; Operator will install temporary engineering controls consisting of perimeter sound walls that shall be used on location during drilling and completion activities. Permanent equipment on location shall be muffled to reduce noise, or shall be appropriately buffered.
Odor mitigationForm: (02A )
400705762
12/5/2014
Per Rule 805: Oil & gas facilities and equipment shall be operated in such a manner that odors and dust do not constitute a nuisance or hazard to public welfare.
Drilling/Completion OperationsForm: (02A )
400705762
12/5/2014
Closed Loop Drilling Systems – Pit Restrictions. Not applicable; a closed-loop system will be used for drilling.
Drilling/Completion OperationsForm: (02A )
400705762
12/5/2014
Blowout preventer equipment (“BOPE”). A double ram and annular preventer will be used during drilling. At least the drilling company shall have a valid well blowout prevention certifications.
Drilling/Completion OperationsForm: (02A )
400705762
12/5/2014
BOPE for well servicing operations. Adequate BOP equipment shall be used. Stabbing valves shall be installed in the event of reverse circulation and shall be prior tested with low and high pressure fluid.
Drilling/Completion OperationsForm: (02A )
400705762
12/5/2014
Pit level indicators. Not applicable; a closed-loop system will be used and no pits shall be dug
Drilling/Completion OperationsForm: (02A )
400705762
12/5/2014
Drill stem tests. Not applicable; no Drill Stem tests are planned
Drilling/Completion OperationsForm: (02A )
400705762
12/5/2014
Control of fire hazards. All materials which are considered fire hazards shall be a minimum of 25’ from the wellhead tanks or separators. Electrical equipment shall comply with API RP 500 and will comply with the current national electrical code. An emergency response plan has been generated for this site.
Drilling/Completion OperationsForm: (02A )
400705762
12/5/2014
Guy line anchors. All guy line anchors shall be brightly marked pursuant to Rule 604.c (2)Q
Final ReclamationForm: (02A )
400705762
12/5/2014
Well site cleared. Within 90-day subsequent to the time of plugging and abandonment of the entire site, superfluous debris and equipment shall be removed from the site.
Final ReclamationForm: (02A )
400705762
12/5/2014
Identification of plugged and abandoned wells. P&A’d wells shall be identified pursuant to 319.a.(5).
Drilling/Completion OperationsForm: (04 )
401118411
10/3/2016
The MLVT will be at least 75 feet from a wellhead, fired vessel, heater-treater, or a compressor with a rating of 200 horsepower or more. It will be placed at least 50 feet from a separator, well test unit, or other non-fired equipment.
Drilling/Completion OperationsForm: (04 )
401118411
10/3/2016
Operator will comply with the testing and re-inspection requirements and associated written standard operating procedures (SOP) listed on the design package.
Drilling/Completion OperationsForm: (04 )
401118411
10/3/2016
Tanks will be filled using a local water source through temporary waterlines. No water will be trucked to location.
Drilling/Completion OperationsForm: (04 )
401118411
10/3/2016
Operator has an MLVT Design Package, certified and sealed by a licensed professional engineer, which is on file in their office and available upon request. The site shall be prepared in accordance with the specifications of the design package prior to tank installation; including ensuring that proper compaction requirements have been met.
Drilling/Completion OperationsForm: (04 )
401118411
10/3/2016
Signs will be posted on the MLVT indicating that the contents are freshwater.
Drilling/Completion OperationsForm: (04 )
401118411
10/3/2016
The MLVT will be operated with a minimum of 1 foot of freeboard at all times.
Drilling/Completion OperationsForm: (04 )
401118411
10/3/2016
Operator will be present during initial filling of the MLVT and the contractor will supervise and inspect the MLVT for leaks during filling.
Drilling/Completion OperationsForm: (04 )
401118411
10/3/2016
Operator or contractor will conduct daily visual inspections of the exterior wall and surrounding area for integrity deficiencies.