TypeSource DocumentConditions of Approval
AgencyForm: (02A )
400547420
3/3/2014
"The proposed location is in a sensitive area with shallow groundwater and the soil type is primarily sand. Secondary containment areas for tanks shall be constructed of steel rings, designed and installed to prevent leakage and resist degradation from erosion or routine operation and shall be constructed with a synthetic or engineered liner that contains all primary containment vessels and flowlines and is mechanically connected to the steel ring to prevent leakage."
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Storm Water/Erosion ControlForm: (02A )
400436169
10/8/2013
This Stormwater Management Plan contains required elements associated with PDC’s construction activities for Area 2, as defined in the CDPS General Permit for Stormwater Discharges Associated with Construction Activity, Authorization to Discharge Under the Colorado Discharge Permit System (Permit No. COR-030000, re-issued and effective July 1, 2007).BMPs for sediment and erosion control will be accomplished through a combination of construction techniques, vegetation and re-vegetation, administrative controls, and structural features.
Storm Water/Erosion ControlForm: (02A )
400547420
3/17/2014
This Stormwater Management Plan contains required elements associated with PDC’s construction activities for Area 2, as defined in the CDPS General Permit for Stormwater Discharges Associated with Construction Activity, Authorization to Discharge Under the Colorado Discharge Permit System (Permit No. COR-030000, reissued and effective July 1, 2007).BMPs for sediment and erosion control will be accomplished through a combination of construction techniques, vegetation and revegetation, administrative controls, and structural features.
Material Handling and Spill PreventionForm: (02A )
400547420
3/17/2014