Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
LOCATION427144Green
1-1H
STRACHAN EXPLORATION INC
83130
AC
3/1/2024
DJ HORIZONTAL NIOBRARA
16950
WELD  123
SESW 1 7N60W 6
427144View Related
 
COGIS - Conditions of Approval Results
No records to display.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Storm Water/Erosion ControlForm: (02A )
400596540
7/30/2014
Material handling and spill prevention procedures and practices will be followed to help prohibit discharges to surface waters. Internal storm water inspections will be conducted per applicable stormwater regulations. Any excessive precipitation accumulation within containment should be removed as appropriate and disposed of properly. Implement appropriate erosion control devices where necessary to minimize erosion of the access road and pad.
Material Handling and Spill PreventionForm: (02A )
400596540
7/30/2014
Operator will ensure 110 percent secondary containment for any volume of fluids contained at the well site during drilling and completion. Operator will implement best practices to contain any unintentional release of fluids.
ConstructionForm: (02A )
400596540
7/30/2014
The location will be fenced and the fenced area will include the fresh water containment. Fresh water for the fresh water storage comes from a water provider, water sources permitted for consumable industrial use.
Drilling/Completion OperationsForm: (02A )
400596540
7/30/2014
Drill cuttings will either be hauled to an approved spread field or waste disposal facility. Drilling fluids will be contained and hauled to an approved waste disposal facility. Flowback and stimulation fluids will be sent to tanks and/or filters to allow the sand to settle out before the fluids are hauled to a state approved disposal facility. Diking, berms, ditches and other forms of containment and diversions will be utilized around tanks, frac tanks, liquids, and/or well pad.
Noise mitigationForm: (04 )
403905948
9/2/2024
Should a noise complaint be received, operator will respond within 48 hours of receipt of the complaint and implement noise level measurement. Operator will also contact the concerned party (if contact information is available) to discuss the complaint and the results of the noise measurements.
Noise mitigationForm: (04 )
403905948
9/2/2024
Operator will comply with the maximum permissible noise levels as outlined in Weld County Code Sec 21-5-435.