Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
LOCATION332832Front Range
11-17 pad
KP KAUFFMAN COMPANY INC
46290
AC
11/1/2024
WATTENBERG
90750
WELD  123
NESW 17 4N66W 6
332832View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
OGLAForm: (02A )
400060686
10/25/2010
Location is in a sensitive area because of proximity to surface water and wetlands; therefore, either a lined drilling pit or closed loop system is required.
OGLAForm: (02A )
400060686
10/25/2010
Operator must implement site-specific best management practices in accordance with good engineering practices, including, but not limited to, construction of a berm or diversion dike, site grading, or other comparable measures, sufficient to protect the surface water/wetlands located 165 feet north of the proposed oil and gas location from a release of drilling, completion, produced fluids, and chemical products.
OGLAForm: (02A )
400060686
10/25/2010
Location is on steep slopes; therefore the cut and fill slopes should be constructed in such a manner to manage site drainage and slope stability. The slopes should be stabilized immediately after the location has been constructed.
OGLAForm: (02A )
400060686
12/20/2010
Construction of the pad and the continuing operation of the facility will not encroach beyond the current boundary of the wetland area to the north of the location.
OGLAForm: (02A )
400060686
12/20/2010
The wetland boundary north of the proposed location will be determined and marked by a qualified professional prior to construction of the well pad.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Storm Water/Erosion ControlForm: (02A )
400060686
12/21/2010
Please see attached conceptual pad plat with indicated storm water retention pond and rockfall for capture area.