| Engineer | Form: (02) 401795620 11/05/2018 | Operator acknowledges the proximity of the listed wells: Operator agrees to: provide mitigation option 1 or 2 (per the DJ Basin Horizontal Offset Policy) to mitigate the situation, ensure all applicable documentation is submitted based on the selected mitigation option chosen, and submit a Form 42 (“OFFSET MITIGATION COMPLETED”) for the remediated wells, referencing the API number of the proposed horizontal well(s) stating what appropriate mitigation occurred and that it has been completed, prior to the hydraulic stimulation of this well.
Two E Ranches 1 (API NO 123-07510)Two E Ranch 1-4 (API NO 123-11195)
NX 1 (API NO 123-11926)Novacek 1 (API NO 123-12347)
Aloysius 34-1 (API NO 123-13109)Lindsay C 33-2 (API NO 123-13155)
Lindsay 33-3 (API NO 123-13156)Lindsay 33-4 (API NO 123-13157)
Lindsay 33-8 (API NO 123-13161)Lindsay 33-5 (API NO 123-13165)
Lindsay 33-6 (API NO 123-13166)Lindsay 33-7 (API NO 123-13167)
Aloysius 34-7 (API NO 123-13238)Lehfeldt C 27-04 (API NO 123-13616)
Lindsay C 33-14 (API NO 123-14700)Lindsay C 33-15 (API NO 123-14713)
Lindsay C 33-9 (API NO 123-14722)Aloysius 34-8 (API NO 123-14752)
Marie D 4-3 (API NO 123-15122)Lehfeldt C 27-5 (API NO 123-15429)
Lehfeldt C 27-12 (API NO 123-15431)Lehfeldt C 27-13 (API NO 123-15432)
Karch Blue D 4-02 (API NO 123-16137)Aloysius C 34-99HZ (API NO 123-32694)
|
| Engineer | Form: (02) 401795620 11/05/2018 | Operator acknowledges the proximity of the following non-operated listed wells: Operator agrees to: provide mitigation option 1 or 2 (per the DJ Basin Horizontal Offset Policy) to mitigate the situation, ensure all applicable documentation is submitted based on the selected mitigation option chosen, and submit a Form 42 (“OFFSET MITIGATION COMPLETED”) for the remediated wells, referencing the API number of the proposed horizontal well(s) stating what appropriate mitigation occurred and that it has been completed, prior to the hydraulic stimulation of this well.
Hanscome C 28-1 (API NO 123-11310)
|
| Engineer | Form: (02) 401795620 11/05/2018 | 1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU (Spud Notice), for the first well/activity on the pad and provide 48 hour spud notice for all subsequent wells drilled on the pad.
2) Comply with Rule 317.j and provide cement coverage from the end of production casing to a minimum of 200' above Niobrara. Verify coverage with cement bond log.
3) Oil-based drilling fluid is to be used only after all aquifers are covered.
|
| Engineer | Form: (02) 401795620 11/05/2018 | Bradenhead tests shall be performed and reported according to the following schedule and Form 17 submitted within 10 days of each test.:
1) Within 60 days of rig release, prior to stimulation.
2) 6 months after rig release, prior to stimulation.
3) Within 30 days of first production, as reported on Form 5A.
|
| Permit | Form: (02) 401795620 12/03/2018 | COGCC COA: Operator will insure the wellbore beyond the unit boundary setback is physically isolated and is not completed. In the Operator Comments on the Form 5A the operator will (1) report the footages from the section lines of the bottom of the completed interval (2) describe how the wellbore beyond the unit boundary setback is physically isolated and (3) certify that none of the wellbore beyond the setback was completed.
|