| Planning | Form: (02 ) 401215185 6/28/2017 | Operator shall submit a Form 42 to the COGCC 48 hours prior to commencement of construction activities. |
| Drilling/Completion Operations | Form: (02 ) 401215185 6/28/2017 | Operator will comply with COGCC Policy for Bradenhead Monitoring During Hydraulic Fracturing Treatments in the Greater Wattenberg Area dated May 29, 2012. |
| Drilling/Completion Operations | Form: (02 ) 401215185 6/28/2017 | Prior to drilling operations, Operator will perform an anti-collision evaluation of all active (producing, shut in, or temporarily abandoned) offset wellbores that have the potential of being within 150 feet of a proposed well prior to drilling operations for the proposed well. Notice shall be given to all offset operators prior to drilling. This anti-collision scan will include definitive MWD or gyro surveys of the offset wells with included error of uncertainty per survey instrument, and compared against the proposed well path with its respective error of uncertainty. If current surveys do not exist for the offset wells, Operator may have gyro surveys conducted to verify bottom hole location. The proposed well will only be drilled if the anti-collision scan results indicate that there is not a risk for collision, or harm to people or the environment. For the proposed well, upon conclusion of drilling operations, an as-constructed gyro survey will be submitted to COGCC with the Form 5. |
| Drilling/Completion Operations | Form: (02 ) 401215185 6/28/2017 | One of the first wells drilled on the pad will be logged with open hole Resistivity Log
and Gamma Ray Log from the kick-off point into the surface casing. All wells on the
pad will have a cement bond log with gamma-ray run on production casing (or on
intermediate casing if production liner is run) into the surface casing. The horizontal
portion of every well will be logged with a measured-while-drilling gamma-ray log. The
Form 5, Completion Report, for each well on the pad will list all logs run and have
those logs attached. The Form 5 for a well without open-hole logs shall clearly state
“No open-hole logs were run” and shall clearly identify (by API#, well name & number)
the well in which open-hole logs were run.
|