Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-41783Horsetail Fed
07F-0639
FUNDARE RESOURCES OPERATING COMPANY LLC
10773
PR
8/1/2017
DJ HORIZONTAL CODELL
16948
WELD  123
SENW 7 10N57W 6
442284View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02 )
400841360
6/16/2015
1) Provide 48 hour notice of MIRU via electronic Form 42. 2) Set 1800' of surface casing. (Base of Upper Pierre aquifer is deeper than proposed 1600’ surface casing. 1780’ in offset 123-05789, gs 4945’). 3) Provide cement coverage to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 4) Run and submit Directional Survey from TD to base of surface casing. Ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
EngineerForm: (04 )
402412529
6/22/2020
Form 17, 402262177, from 12/12/19 reported bradenhead pressure of 398 psi that blew down to 25 psi with continuous flow and that samples were taken. To date the analytical results are not appearing in the COGCC database, please submit results by 7/22/2020.
EngineerForm: (04 )
402412529
6/22/2020
1. Operator shall implement measures to control venting, to protect health and safety, and to ensure that vapors and odors from well operations do not constitute a nuisance or hazard to public welfare. 2. Prior to starting bradenhead mitigation, if a sample has not been collected within the last twelve months collect bradenhead and production gas samples for laboratory analysis. Sampling shall comply with Operator Guidance - Bradenhead Testing and Reporting Instructions, Appendix A: Liquid and Gas Sampling. Copies of all final laboratory analytical results shall be provided to the COGCC within three months of collecting the samples. 3. Operator shall implement measures to get an initial estimate of the gas flow rate and/or volume from the bradenhead. During the shut-in period record pressure data to adequately characterize the build-up. This mitigation plan may be used for six consecutive months from the test date on the Form 17, 12/12/2019. 4. At the conclusion of the six months (6/12/2020), conduct a new bradenhead test and submit the Form 17 within ten days of the test and submit a Form 4 Sundry that summarizes current well condition. The sundry should include details of the future plans and the flow rate information and pressure data.
EngineerForm: (04 )
402588471
3/4/2021
Sundry lacks detail of work to date. Gas analysis submitted 2/4/2021 (samples date of 12/2/2020) indicates the bradenhead gas to be thermogenic in origin. Operator to submit a mitigation plan based on these results.
EngineerForm: (04 )
402815098
12/19/2022
Bradenhead pressure mitigation via production facilities planned for Q3 2021. The results of this mitigation to date as well as the annual bradenhead test and gas sample analysis for 2022 are due by 12/31/22. The results should be summited via sundry and are to include volumes, rates and pressures maintained on the bradenhead in addition to a summary of the monthly monitoring data.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
PlanningForm: (02 )
400841360
6/30/2015
Wells Planned within 1500 feet are shown on the multi-well plan map.
Storm Water/Erosion ControlForm: (02 )
400841360
6/30/2015
Stormwater management plans (SWMP) are in place to address construction, drilling and operations associated with oil and gas development throughout the State of Colorado. BMPs will be constructed as necessary to prevent stormwater from leaving the construction site. BMPs used will vary according to the location, and will remain until the pad is reclaimed.
Material Handling and Spill PreventionForm: (02 )
400841360
6/30/2015
Spill Prevention Control and Countermeasures (SPCC) plans are in place to address any possible spill associated with oil and gas operations throughout the State of Colorado. • Materials and fluids will be stored in a neat and orderly fashion. • Waste will be collected regularly and disposed of at an offsite facility. • Prompt cleanup is required of spills to minimize waste materials entering the stormwater runoff. • Drip pans will be used during fueling and maintenance to contain spills or leaks. • Cleanup of trash and discarded material will be done at the end of the work day. • Cleanup will consist of monitoring the road, location and any other work areas. • Material to be cleaned up includes trash, scrap, and contaminated soil.
Drilling/Completion OperationsForm: (02 )
400841360
6/30/2015
One of the first wells drilled on the pad will be logged with an open-hole resistivity log with gamma-ray from TD to into the surface casing. All wells on the pad will have a cement bond log with gamma-ray run on the production casing (or intermediate casing if production liner is run). All wells on the pad will have the horizontal portion of the wellbore logged with a measured-while-drilling log with gamma-ray. The Form 5, Completion Report, for each well on the pad will list all logs run and have those logs attached. The Form 5 for a well without open-hole logs shall clearly state “No open-hole logs were run.” The Form 5 for a well without open-hole logs shall clearly identify (by API#, well name &number) the well in which open-hole logs were run.