Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-39889Antelope
A11-E14-15HNC
BONANZA CREEK ENERGY OPERATING COMPANY LLC
8960
SI
12/1/2025
WATTENBERG
90750
WELD  123
NWNW 15 5N62W 6
429977View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
400627587
06/23/2014
1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU. 2) Comply with Rule 317.i and provide cement coverage from end of 7” casing to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 3) Run and submit Directional Survey from TD to base of surface casing. The operator shall comply with Rule 321, and it shall be the operator’s responsibility to ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
PermitForm: (02)
400627587
07/03/2014
Open hole resistivity and gamma logs shall be run to describe the stratigraphy of the entire well bore and to adequately verify the setting depth of surface casing and aquifer coverage. On a multi-well pad, these open hole logs are only required on one of the first wells drilled on the pad and the Drilling Completion Report - Form 5 for every well on the pad shall identify which well was logged.
EngineerForm: (04)
404059902
02/28/2025
Alternative MIT is granted for a period ending 3/31/2026. If not returned to production by 3/31/2026 operator shall perform an MIT. Due to the removal of surface facilities and sales lines, this well is considered Temporarily Abandoned. All other temporary abandonment requirements remain in place including a TA sundry, a 5A, and Form 7 reporting. Furthermore, all Inactive well requirements remain in full effect.
EngineerForm: (04)
404145946
04/11/2025
1) Well last produced January 2025, and has been designated as Inactive. Within 6 months of a Well becoming Inactive action must be taken. No later than January 2026, this well must: A. Be plugged and Abandoned, B. Return to production so that it is no longer an Inactive Well, C. Have an approved Form 5B, Inactive Well Notice, D. Be designated as Out of Service by submitting a Form 6A, Out of Service Designation.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Drilling/Completion OperationsForm: (02 )
400627587
7/15/2014
Open hole resistivity and gamma logs shall be run to describe the stratigraphy of the entire well bore and to adequately verify the setting depth of surface casing and aquifer coverage on either this well or one of the other remaining proposed offset wells not yet drilled on this pad. The Drilling Completion Report - Form 5 for every well on the pad shall identify which well was logged.