WELL05-123-38453STATE
4-16-9-60
VERDAD RESOURCES LLC
10651
SI
11/1/2022
DJ HORIZONTAL NIOBRARA
16950
WELD  123
NWNW 16 9N60W 6
417324View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
400490507
11/20/2013
Operator acknowledges the proximity of the non-operated STATE 1-16 (API # 123-07196) well. Operater has made application to re-enter/re-plug this well, Doc. # 400508232. Operator assures that this offset will be remediated per the DJ Basin Horizontal Offset Policy (option 3) or operator will address this well with mitigation option 4. Operator will submit a Form 42 (“OTHER – AS SPECIFIED BY PERMIT CONDITION”) stating what appropriate mitigation occurred and that it has been completed, prior to the hydraulic stimulation of this well.
EngineerForm: (02)
400490507
11/20/2013
1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU. 2) Comply with Rule 317.i and provide cement coverage from TD to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 3) Comply with Rule 321. Run and submit Directional Survey from TD to base of surface casing. Ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Pre-ConstructionForm: (02 )
400490507
11/21/2013
The COGCC to be notified 48 hours prior to construction the Fresh Water Storage Pit. In addition, will obtain permit approval prior to constrution.
Storm Water/Erosion ControlForm: (02 )
400490507
11/21/2013
Operator has designed the well pad with insloping and a storm water control ditch to prevent sotm water run-on/runoff and release of fluids from the lcoation. See attached Construction Layout Drawing.
Material Handling and Spill PreventionForm: (02 )
400490507
11/21/2013
Operator will ensure 110 percent secondary containment for any volume of fluids contaed at the well site during drilling and completion. Operator will implement best amangement practices to contain any unintentional release of fluids. Operator shall not allow any fluids to flow back to the Fresh Water Storage Pit/Pond.
ConstructionForm: (02 )
400490507
11/21/2013
The location will be fenced and the fenced area will include the Fresh Water Storage Pit.
Drilling/Completion OperationsForm: (02 )
400490507
11/21/2013
Fresh water for the Fresh Water Storage Pit comes from water provider; Is trucked in. Water sources permitted for consumable industrial use. Fresh Water Storage Pit shall contain fresh water only and signage prohibiting theuse of the pit for any fluid that does not come from municipla, irrigation or surface water source. Operator will implement interim relcation measures immediately after construction of the location to stabilize cut and fill slopes, stablize the topsoil and spoil stockpiles, establish desirable vegetation and control weeds on the location.