Permit | Form: (02 ) 400445955 8/7/2013 | Operator must meet water well testing requirements per Rule 318A |
Engineer | Form: (02 ) 400445955 9/9/2013 | 1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU.
2) Comply with Rule 317.i and provide cement coverage from end of 7” casing to a minimum of 200' above Niobrara and from 200’ below the Sussex to 200’ above Sussex. Verify coverage with cement bond log.
3) Comply with Rule 321. Run and submit Directional Survey from TD to base of surface casing. Ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
|
Engineer | Form: (02 ) 400445955 9/9/2013 | Operator acknowledges the proximity of the following wells: Conner 23-34 API # 123-11470, Ranchero 1 API # 123-08576, McConahay 43-34 API # 123-19637, Darlenne 1 API # 123-10002, Seymour 34-34 API # 123-19554, Conner 41-4 API # 123-21008. Operator agrees to: provide mitigation option 1, 2 or 3 (per the DJ Basin Horizontal Offset Policy) to mitigate the situation, ensure all applicable documentation is submitted based on the selected mitigation option chosen, and submit a Form 42 (“OTHER – AS SPECIFIED BY PERMIT CONDITION”) stating what appropriate mitigation occurred and that it has been completed, prior to the hydraulic stimulation of this well. |
Engineer | Form: (02 ) 400445955 9/9/2013 | Note: Request for omission of Open Hole Logging not accepted. A full suite of open hole logs is required for one well on this pad.
Operator will place an explicit comment on the Drilling Completion Report documenting which well on this pad was logged with a full suite of open hole logs.
|