| Permit | Form: (02) 400380297 03/12/2013 | Operator must meet water well testing requirements per Rule 318A.
|
| Engineer | Form: (02) 400380297 03/19/2013 | Operator will place an explicit comment on the Drilling Completion Report documenting which well was logged with a full suite of open hole logs. |
| Engineer | Form: (02) 400380297 03/21/2013 | 1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU.
2) Comply with Rule 317.i and provide cement coverage from end of 7" casing to a minimum of 200' above Niobrara. Verify coverage with cement bond log.
3) Comply with Rule 321. Run and submit Directional Survey from TD to base of surface casing. Ensure that the wellbore
complies with setback requirements in commission orders or rules prior to producing the well. |
| Engineer | Form: (02) 400380297 03/21/2013 | Operator will place an explicit comment on the Drilling Completion Report documenting which well on this pad was logged with a full suite of open hole logs. |
| Engineer | Form: (02) 400380297 03/21/2013 | No offset wells within 500' |