| Permit | Form: (02) 400351896 12/18/2012 | Operator must meet water well testing requirements per Rule 318A. |
| Engineer | Form: (02) 400351896 12/18/2012 | 1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU.
2) Comply with Rule 317.i and provide cement coverage from end of 7” casing to a minimum of 200' above Niobrara. Verify coverage with cement bond log.
3) Comply with Rule 321. Run and submit Directional Survey from TD to base of surface casing. Ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
|
| Engineer | Form: (02) 400583861 04/07/2014 | 1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU.
2) Comply with Rule 317.i and provide cement coverage from the bottom of the production casing to a minimum of 200' above Niobrara. Verify coverage with cement bond log.
3) Run and submit Directional Survey from TD to base of surface casing. The operator shall comply with Rule 321, and it shall be the operator’s responsibility to ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
4) Submit appropriate Form 5 (00) and Form 5(01) for the wellbores.
|
| Engineer | Form: (04) 401208249 05/17/2017 | • Attachment for 4.5" casing appears to be proposal not summary.
|