| Engineer | Form: (02) 400311627 10/15/2012 | 1)Provide notice of MIRU via an electronic Form 42.
2)Comply with Rule 317.i and provide cement coverage from the 7” casing TD to a minimum of 200' above the Niobrara. Verify coverage with a cement bond log.
|
| Permit | Form: (02) 400311627 10/16/2012 | Operator must meet water well testing requirements per Rule 318A.
|
| Permit | Form: (02) 400311627 10/16/2012 | Operator will comply with COGCC Policy for Bradenhead Monitoring During Hydraulic Fracturing Treatments in the Greater Wattenberg Area dated May 29, 2012. (attached)
|