Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-36243Waves
1H
STRACHAN EXPLORATION INC
83130
PR
10/1/2024
DJ HORIZONTAL NIOBRARA
16950
WELD  123
SWSW 23 7N60W 6
430662View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
400327295
10/24/2012
1) Provide 48 hour notice prior to spud via electronic Form 42. 2) Provide cement coverage from base of intermediate casing to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 3) Run and submit Directional Survey from TD to base of surface casing. Ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
EngineerForm: (04)
402045305
04/12/2022
For combustion of gas due to upset conditions, criteria set forth by 903.d.(1) limiting the duration and requiring records being kept of those instances where combustion was necessary must be followed after January 15, 2021.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
PlanningForm: (02 )
400327295
10/30/2012
The Pit Report on Form 15 will be submitted within 30 days of construction of the fresh water storage pit.
Drilling/Completion OperationsForm: (02 )
400327295
10/30/2012
Operator will ensure 110 percent secondary containment for any volume of fluids contained at the well site during drilling and completion. Operator will implement best management practices to contain any unintentional release of fluids. Fresh water for the Fresh Water Storage Pit comes from a water provider; water sources permitted for consumable industrial use.
ConstructionForm: (02 )
400327295
10/30/2012
Operator has designed the well pad with insloping and a storm water control ditch to prevent storm water run-on/run-off and the release of fluids for the location. See attached Construction Layout Drawing. The location will be fenced and the fenced area will include the Fresh Water Storage Pit. The COGCC will be notified 48 hours prior to construction of the Fresh Water Storage Pit.