WELL05-123-34084Antelope
S-17
BONANZA CREEK ENERGY OPERATING COMPANY LLC
8960
AL
3/6/2014
WATTENBERG
90750
WELD  123
NESE 17 5N62W 6
424559View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
400182032
07/20/2011
1) Note surface casing setting depth change from 410’ to 470’. Increase cement coverage accordingly and cement to surface. 2) Provide 24 hour notice of MIRU to Bo Brown via e-mail at bo.brown@state.co.us. 3) Comply with Rule 317.i and provide cement coverage from TD to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 4) Comply with Rule 321. Run and submit Directional Survey from TD to base of surface casing. Ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
 
COGIS - Best Management Practice Results
No records to display.