Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-33539FRENCH LAKE 3-63-16
1H
KERR MCGEE OIL & GAS ONSHORE LP
47120
SI
1/1/2024
WATTENBERG
90750
WELD  123
NWNW 16 3N63W 6
423218View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
400142908
05/10/2011
1) Provide 24 hour notice of MIRU to Jim Precup at 303-469-1902 or e-mail at james.precup@state.co.us 2) Comply with Rule 317.i and provide cement coverage from TD to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 3) Comply with Rule 321. Run and submit Directional Survey from TD to base of surface casing. Ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
EngineerForm: (04)
400983945
05/26/2016
1) The flaring of natural gas shall be allowed in accordance with COGCC Rule 912. The combustion device must have a design destruction efficiency of at least 98% for hydrocarbons. 2) Notify the local emergency dispatch or the local governmental designee of any natural gas flaring. 3) Submit updated requests to flare to COGCC on Form 4 (Sundry Notice), which discuss whether or not any new gathering systems or increased development of the field have changed pipeline economics such that installation of a new pipeline would be an economically viable option in lieu of continued flaring. 4) The operator is required to obtain and maintain any required air permits from CDPHE. 5) The flare volumes shall be reported by Form 7, Operator’s Monthly Report of Operations.
EngineerForm: (04)
400983945
05/26/2016
This approval is good for one year and new appication must be made before February 8, 2017.
EngineerForm: (04)
401200184
03/16/2017
1) Flaring of natural gas shall comply with COGCC Rule 912. 2) Submit requests to flare annually to COGCC on Form 4 (Sundry Notice), which discusses timing to connect to sales line, plans to develop infrastructure, and justification for continued venting/flaring. Provide gas analysis including H2S with each Sundry Notice. 3) Report flaring volumes on Form 7, Operator’s Monthly Report of Operations. 4) The operator is required to obtain and maintain any required air permits from CDPHE. 5) The expectation for permanent flares controlling separators will be an enclosed combustion device with a 98% design destruction efficiency for hydrocarbons. 6) Notify the local emergency dispatch or the local governmental designee of natural gas flaring.
EngineerForm: (04)
401200184
03/16/2017
This approval is good for one year and new application must be made before February 1, 2018.
EngineerForm: (04)
401531984
04/03/2020
1) Flaring of natural gas shall comply with COGCC Rule 912. 2) Submit requests to flare annually to COGCC on Form 4 (Sundry Notice), which discusses timing to connect to sales line, plans to develop infrastructure, and justification for continued venting/flaring. Provide gas analysis including H2S with each Sundry Notice. 3) Report metered flaring volumes on Form 7, Operator’s Monthly Report of Operations. 4) The operator is required to obtain and maintain any required air permits from CDPHE. 5) The expectation for permanent flares controlling separators will be an enclosed combustion device with a 98% design destruction efficiency for hydrocarbons. Operator shall manage this well so that production volumes do not exceed the combustor capacity. 6) Notify the local emergency dispatch or the local governmental designee of natural gas flaring.
EngineerForm: (04)
401531984
04/03/2020
Additional requests will detail field development within 10 miles of this well and what infrastructure is in place and actions have been taken to access infrastructure.
EngineerForm: (04)
401531984
04/03/2020
This approval is good for one year and new application must be made before March 1, 2020.
 
COGIS - Best Management Practice Results
No records to display.