Agency | Form: (02 ) 2581015 4/13/2010 | 1) Note surface casing setting depth change from 800’ to 880’. Increase cement coverage accordingly. 2) Provide 24 hour notice of MIRU to Ed Binkley at 970-506-9834 or e-mail at ed.binkley@state.co.us 3) Comply with Rule 317.i and provide cement coverage from TD to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 4) Run and submit Directional Survey from TD to base of surface casing. The operator shall comply with Rule 321, and it shall be the operator’s responsibility to ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well. |
Agency | Form: (02 ) 2581015 4/13/2010 | 1) Note surface casing setting depth change from 800’ to 880’. Increase cement coverage accordingly. 2) Provide 24 hour notice of MIRU to Ed Binkley at 970-506-9834 or e-mail at ed.binkley@state.co.us 3) Comply with Rule 317.i and provide cement coverage from TD to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 4) Run and submit Directional Survey from TD to base of surface casing. The operator shall comply with Rule 321, and it shall be the operator’s responsibility to ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well. |
Agency | Form: (02 ) 1760653 4/14/2010 | 1) Note surface casing setting depth change from 800’ to 880’. Increase cement coverage accordingly. 2) Provide 24 hour notice of MIRU to Ed Binkley at 970-506-9834 or e-mail at ed.binkley@state.co.us 3) Comply with Rule 317.i and provide cement coverage from TD to a minimum of 200' above Niobrara. Verify coverage with cement bond log. |
Engineer | Form: (04 ) 400908533 4/24/2016 | 1) Flaring of natural gas shall comply with COGCC Rule 912.
2) Submit requests to flare annually to COGCC on Form 4 (Sundry Notice), which discusses timing to connect to sales line, plans to develop infrastructure, and justification for continued venting/flaring. Provide gas analysis including H2S with each Sundry Notice.
3) Report flaring volumes on Form 7, Operator’s Monthly Report of Operations.
4) The operator is required to obtain and maintain any required air permits from CDPHE.
5) Notify the local emergency dispatch or the local governmental designee of natural gas flaring. |
Engineer | Form: (04 ) 401383727 10/4/2018 | 1) Flaring of natural gas shall comply with COGCC Rule 912.
2) Report metered volumes of gas flared on the Form 7, Operators Report of Monthly Operations.
3) Operator will use an enclosed combustion device with a 98% design destruction efficiency for hydrocarbons. Operator shall manage this well so that production volumes do not exceed combustor capacity.
4) Provide the local emergency dispatch or the local governmental designee prior notice of natural gas flaring by supplying them with a copy of the approved Sundry Notice and all attachments. Operator shall notify local government designee and emergency dispatch prior to flaring when flaring can be reasonably anticipated, or as soon as possible, but in no event more than two (2) hours after the flaring occurs.
5) Approval of this Sundry Notice applies to this well only.
6) Well completion practices in Rule 805.b.(3) shall apply to future well completions on this Oil and Gas Location. When commercial quantities of salable quality gas are achieved at any future well, the gas shall be immediately directed to a sales line, or shut in and conserved, or a variance from Rule 805.b.(3)C must be obtained to produce the well. The Rule 912 notice and approval requirements apply regardless of a variance from Rule 805.b.(3)C. |
Engineer | Form: (04 ) 402517012 1/13/2022 | All existing, approved Form 4s to vent or flare production gas expire on Jan 15, 2022.
Must have an approved gas capture plan or variance approved by the Commission prior to January 15, 2022. Must be complete and provide all necessary details. Without prior approval - well is to be shut in and conserved until gas capture plan or variance is approved.
|
Engineer | Form: (04 ) 403342414 6/19/2023 | This well is approved for a 60 day productivity test to produce and document gas
volumes by metering gas. This approval is for 60 consecutive calendar days. Gas
volumes will be reported via Form 4 Sundry Notice on the well, documenting location
gas use requirements. Without documented gas volumes and a demonstration of
beneficial on site use, this well is to be shut in and a variance sought for flaring. |
Engineer | Form: (04 ) 403342414 6/19/2023 | Gas Capture Plans should be filed on Location ID rather than Well ID. |