Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-29379NELSON
33-35
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
5/24/2018
SPINDLE
77900
FREDERICK/WELD  123
NESW 35 2N68W 6
336181View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (04 )
400525266
12/11/2013
The additional cement referenced shall be placed as indicated and comply with Rule 317.i. The placed cement shall be verified with a CBL and documented with a Form 5.
EngineerForm: (04 )
400738287
11/21/2014
Please submit form 17 for previous tests and after each new test.
EngineerForm: (04 )
400860321
6/30/2015
Collect production and bradenhead gas samples and perform gas composition and stable isotope analysis. The stable isotope analysis should include the d13C1, d13C2, d13C3, d13IC4, d13NC4 , d13IC5 , d13NC5, d13C6+ and dDC1.
EngineerForm: (06 )
401527005
2/21/2018
1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) Properly abandon all flowlines as per Rule 1103. File electronic Form 42 once abandonment complete. 3) Operator shall implement measures to control unnecessary and excessive venting, to protect the health and safety of the public, and to ensure that vapors and odors from well plugging operations do not constitute a nuisance or hazard to public welfare. 4) Submit a copy of all logs run during plugging operations with Form 6 Subsequent Report of Abandonment. 5) After pumping squeeze, shut down and wait on cement at minimum 8 hours; verify gas migration has been eliminated. If evidence of gas migration or pressure remains contact COGCC Engineer for an update to plugging orders.
EngineerForm: (06 )
401527005
2/21/2018
Prior to starting plugging operations a bradenhead test shall be performed. 1) If, before opening the bradenhead valve, the beginning pressure is greater than 25 psi, sampling is required. 2) If pressure remains at the conclusion of the test, or if any liquids were present during the test, sampling is required. The Form 17 shall be submitted within 10 days of the test. Sampling shall comply with Operator Guidance - Bradenhead Testing and Reporting Instructions. If samples are collected, copies of all final laboratory analytical results shall be provided to the COGCC within three (3) months of collecting the samples.
 
COGIS - Best Management Practice Results
No records to display.