WELL05-123-28185PIONEER
9-12
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
4/11/2017
WATTENBERG
90750
WELD  123
SESE 12 2N65W 6
336089View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (04 )
400546775
1/30/2014
The additional cement referenced shall be placed as indicated and comply with Rule 317.i. The placed cement shall be verified with a CBL and documented with a Form 5 Drilling Completion Report.
EngineerForm: (06 )
401150612
11/22/2016
1) Prior to starting plugging operations a bradenhead test shall be performed. If the beginning pressure is greater than 25 psi, or if pressure remains at the conclusion of the test, or if any liquids were present contact COGCC Engineer for sampling requirements. The Form 17 shall be submitted within 10 days of the test. 2) Provide 48 hour notice of plugging MIRU via electronic Form 42. 3) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete. 4) Please submit gyro survey data with Form 6 (s) Subsequent Report of Abandonment. 5) Production casing stub plug is also surface casing shoe plug, this plug must be tagged at 850’ or shallower. Leave at least 100’ of cement in the wellbore for each plug.
 