WELL05-123-21378WELLS RANCH
23-11
PDC ENERGY INC
69175
PA
12/12/2017
WATTENBERG
90750
WELD  123
NESW 11 5N63W 6
331839View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
401406562
10/10/2017
1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) For the 650’ plug: pump plug and displace. If surface casing plug is not circulated to surface then tag plug – must be at 349’ or shallower and provide 10 sx plug at the surface. Leave at least 100’ of cement in the casing for each plug. 3) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete.
EngineerForm: (06)
401406562
10/10/2017
1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) For the 670’ plug: pump plug and displace. If surface casing plug is not circulated to surface then tag plug – must be at 363’ or shallower and provide 10 sx plug at the surface. Leave at least 100’ of cement in the casing for each plug. 3) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete.
 