WELL05-123-21035MACE
11-4
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
4/13/2017
WATTENBERG
90750
WELD  123
NESW 4 1N67W 6
332960View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06 )
401153175
12/21/2016
1) Prior to starting plugging operations a bradenhead test shall be performed. If the beginning pressure is greater than 25 psi, or if pressure remains at the conclusion of the test, or if any liquids were present contact COGCC Engineer for sampling requirements. The Form 17 shall be submitted within 10 days of the test. 2) Provide 48 hour notice of plugging MIRU via electronic Form 42. 3) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete. 4) Production casing stub plug is also surface casing shoe plug, this plug must be tagged at 668’ or shallower. Leave at least 100’ of cement in the wellbore for each plug.
 