WELL05-123-19078HSR-CAMP
1-24
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
9/18/2014
WATTENBERG
90750
WELD  123
SENE 24 3N67W 6
336160View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
400587419
04/11/2014
Note changes to plugging procedure: 1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) For 4990’ plug: pump plug and displace, shut-in, WOC 4 hours and tag plug – must be 4360' or shallower. Leave at least 100’ cement in the casing for each plug. 3) For 1100’ plug: pump plug and displace, shut-in, WOC 4 hours and tag plug – must be 570' or shallower, provide minimum 10 sx plug at the surface. 4) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete.
 