Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-16393MAGNESS RED W
6-4
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
6/6/2017
WATTENBERG
90750
WELD  123
NWNW 6 2N66W 6
328758View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
401158459
01/10/2017
1) Prior to starting plugging operations a bradenhead test shall be performed. If the beginning pressure is greater than 25 psi, or if pressure remains at the conclusion of the test, or if any liquids were present contact COGCC Engineer for sampling requirements. The Form 17 shall be submitted within 10 days of the test. 2) Provide 48 hour notice of plugging MIRU via electronic Form 42. 3) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete. 4) Operator indicated the well has a gyro from October 2014 that has not been submitted to COGCC. Submit gyro survey data with Form 6 Subsequent Report of Abandonment. 5) No CBL on file with COGCC. Must submit CBL that verifies TOC 6850' or shallower and stage cement with Form 6 Subsequent Report of Abandonment. 6) Tag exisitng bridge plug at 7244' and pressure test before placing cement on top. If mechanical device is not confirmed before placing cement then tag top of cement plug. 7) Leave at least 100’ of cement in the wellbore for each plug.
 
COGIS - Best Management Practice Results
No records to display.