Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-15162FRANK
H21-16
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
11/18/2015
WATTENBERG
90750
WELD  123
SESE 21 3N65W 6
327797View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
400902317
09/25/2015
1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU. 2) For 960' plug: pump plug and displace, shut-in, WOC 4 hours and tag plug – must be 450’ or shallower. 3) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete. 4) Submit corrected Operator's Monthly Production Reports (Form 7) required for compliance with Rule 309 within 30 days. 5) Submit contractor report for setting of RBP@ 6720' with Form 6 (s) Subsequent Report of Abandonment.
 
COGIS - Best Management Practice Results
No records to display.