Agency | Form: (02 ) 2582196 5/4/2010 | 1) Provide 24 hour notice of MIRU to Bo Brown at 970-330-6085 or e-mail at bobrown@state.co.us 2) Provide remedial cement from 4730’ - 4210’ (Sussex), and 920’ – 610’ (Fox Hills, last joint casing fell off bottom to 825’-870’). Verify w/ CBL. 3) Recomplete cannot be performed without approved Form 2. |
Agency | Form: (02 ) 2582196 5/4/2010 | 1) Provide 24 hour notice of MIRU to Bo Brown at 970-330-6085 or e-mail at bobrown@state.co.us 2) Provide remedial cement from 4730’ - 4210’ (Sussex), and 920’ – 610’ (Fox Hills, last joint casing fell off bottom to 825’-870’). Verify w/ CBL. Also submit CBL for Niobrara TOC stated as 6100' by CBL. 3) Recomplete cannot be performed without approved Form 2. |
Agency | Form: (02 ) 2582196 5/4/2010 | 1) Provide 24 hour notice of MIRU to Bo Brown at 970-330-6085 or e-mail at bobrown@state.co.us
2) Provide remedial cement from 4730’ - 4210’ (Sussex), and 720’ – 610’ (Fox Hills, SC shoe at 665'. Last joint casing fell off bottom to 825’-870’). Verify w/ CBL. Also submit CBL referenced for Niobrara TOC stated as 6100'. |
Engineer | Form: (06 ) 400724836 1/2/2015 | 1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU.
2) If unable to pull casing contact COGCC for plugging modifications.
3) For 1290' plug: pump plug and displace, shut-in, WOC 4 hours and tag plug – must be 600’ or shallower.
4) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete.
5) Please submit gyro survey data with Form 6 (s) Subsequent Report of Abandonment.
6) No CBL on file. Please submit existing CBL with Form 6 (s) Subsequent Report of Abandonment. |