WELL05-123-12159JOHNSON
1
NOBLE ENERGY INC
100322
PA
3/15/2014
WATTENBERG
90750
WELD  123
SWSE 11 6N66W 6
322850View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06 )
400500497
10/30/2013
Note changes to plugging procedure. 1) Provide 24 hour notice of MIRU to Jim Precup at 303 726-3822 or e-mail at james.precup@state.co.us. 2) For 470’ plug: if cement is not pumped to surface, shut-in, WOC 4 hours and tag plug – must be 356’ or shallower. Leave at least 100’ cement in the casing for each plug. 3) Properly abandon flowlines as per Rule 1103.
 