COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06 )
400525773
12/12/2013
1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU. 2) If unable to pull casing, contact COGCC for plugging modifications. 3) Leave at least 100’ cement in the wellbore for each plug. 4) For 1410' plug: pump plug and displace, shut-in, WOC 4 hours and tag plug – must be 950’ or shallower. 5) Properly abandon flowlines as per Rule 1103.
 
COGIS - Best Management Practice Results
No records to display.