Engineer | Form: (06 ) 2285657 12/20/2011 | 1) Provide 24 hour notice of MIRU to Mike Hickey at 970-302-1024 or e-mail at Mike.Hickey@state.co.us.
2) For 720’ plugs: perforate casing, pump plug and displace, shut-in, WOC 4 hours and tag plug – must be 490’ or shallower. Leave at least 100’ cement in the casing for each plug.
3) Properly abandon flowlines as per Rule 1103. |
Engineer | Form: (06 ) 401545884 7/12/2018 | Operator shall implement measures to control unnecessary and excessive venting, to
protect the health and safety of the public, and to ensure that vapors and odors from
well plugging operations do not constitute a nuisance or hazard to public welfare. |
Engineer | Form: (06 ) 401545884 7/12/2018 | 1) Provide 48 hour notice of plugging MIRU via electronic Form 42. |
Engineer | Form: (06 ) 401958852 3/12/2019 | Operator shall implement measures to control venting, to protect health and safety, and to ensure that vapors and odors from well plugging operations do not constitute a nuisance or hazard to public welfare. |
Engineer | Form: (06 ) 401958852 3/12/2019 | 1) Provide 48 hour notice of plugging MIRU via electronic Form 42. |