WELL05-123-10417PRATT
1
KP KAUFFMAN COMPANY INC
46290
PA
10/21/2015
WATTENBERG
90750
ERIE/WELD  123
NESW 29 1N68W 6
318976View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
PermitForm: (06)
400894824
09/23/2015
Production records need to be corrected prior to the approval of the Subsequent Report of Abandonment (Form 6). (Missing Codell from 9/28/1983 to 7/18/2001 showing it as TA'd thru Jun 2001)
EngineerForm: (06)
400894824
10/02/2015
Note change in plugging procedure: 1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU. 2) Increase cement used to repair casing leak from 25 sxs to 50 sxs. 3) Contact COGCC if switching to a pull casing plugging, as this is a common way to resolve problems with casing leaks. 4) The Sussex formation is productive within one mile of this well. Therefore, cement isolation, which does not currently exist across it, must be provided, by using a perforate and squeeze or equivalent method so that at a minimum there is cement from 200’ below to 200’ above the Sussex formation. 5) For 1075' shoe plug perforate at least 50' below surface casing shoe to ensure annulus coverage. 6) For 1075' plug: pump plug and displace, shut-in, WOC 4 hours and tag plug – must be 910’ or shallower. If shoe plug not circulated to surface then place 10-40 sx inside casing at surface. Leave at least 100' for each plug. 7) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete. 8) Please submit existing gyro survey data with Form 6 (s) Subsequent Report of Abandonment. 9) Provide an “As Plugged” wellbore diagram identifying the specific plugging completed.
 
COGIS - Best Management Practice Results
No records to display.