Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-07900MARGUERITE TOTEMS UNIT
1
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
8/21/2013
WATTENBERG
90750
WELD  123
SWSW 20 1N67W 6
317877View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
400440926
08/01/2013
If the CBL (Step 14 of the submitted plugging procedure) shows inadequate cement coverage of the Shannon or Sussex Formations, the planned cement plug inside the casing from 5654’ to 4678’ must be adjusted to achieve cement coverage, both inside the 4-1/2” production casing and in the 4-1/2” casing by 7-7/8” hole annulus, 200’ above the Sussex Formation. Provide a copy of the CBL along with the Form 6, Subsequent Report of Abandonment, within 30 days after abandonment of this well.
 
COGIS - Best Management Practice Results
No records to display.