Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-07853PREMIUM TURKEY FARMS B
1
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
10/22/2014
SPINDLE
77900
WELD  123
NENE 22 2N67W 6
317852View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
400679844
09/14/2014
1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU. 2) Run CBL to determine if adequate coverage over Sussex exists. If TOC is less than 4400' add additional cement by perforating and squeezing. 3) If unable to pull casing contact COGCC for plugging modifications. 4) For 1400' plug: pump plug and displace, shut-in, WOC 4 hours and tag plug – must be 600’ or shallower. 5) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete. 6) Please submit gyro survey data with Form 6 (s) Subsequent Report of Abandonment.
 
COGIS - Best Management Practice Results
No records to display.