Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-11933WEAVER RIDGE
23-7H
ROBERT L BAYLESS PRODUCER LLC
6720
PR
12/1/2025
PICEANCE HORIZONTAL MANCOS
68808
RIO BLANCO  103
SWNE 23 1S104W 6
316503View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
400257212
04/25/2012
1)COMPLIANCE WITH THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY IS REQUIRED. 2)THE PROPOSED SURFACE CASING IS MORE THAN 50' BELOW THE DEPTH OF THE DEEPEST WATER WELL WITHIN 1MILE OF THE SURFACE LOCATION WHEN CORRECTED FOR ELEVATION DIFFERENCES. THE DEEPEST WATER WELL WITHIN 1 MILE IS 000 FEET DEEP.
PermitForm: (02)
400257212
05/16/2012
Before placing oil/salt based muds in a pit, operator must file and receive prior approval of a Pit Permit, Form 15. COGCC regulations regarding pit permits can be found in Rule 903.a.(3). PIT PERMITTING/REPORTING REQUIREMENTS.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Final ReclamationForm: (02 )
400257212
6/22/2012
The following plan describe surface reclamation actions for vegetation and soil rehabilitation, scarification and reseeding of the pads "apron" (the area surrounding the pad site, including the cut and fill, topsoil and excess materials stockpile sites, etc.). The BLM will be contacted prior to commencement of any reclamation operations. The direction and specific work orders spelled out in this plan will apply to the existing well pad on the cited well. The overall goals and objectives of this plan for the Weaver Ridge 23-7H well pad site and any additional infrastructure associated with this well are to a)Minimize the surface impacts to other resources and authorized uses in the vicinity of the well pad site, b)Restore the landform and natural process to re-establish and sustain a pre-disturbance productivity of the site, consistent with the 1997 White River Resource Management Plan (WRRMP), c) Apply all Conditions of Approval (COA)s which are outlined in the Record of Decision/EA associated with this well and also consider additional applicable BLM's Conditions of Approval (WRRMP, Appendix 2) as a baseline to minimize surface impacts and enhance subsequent reclamation actions, and d)Apply appropriate new techniques and/or methodologies that would minimize surface disturbance and enhance reclamation success. This plan outlines new and additional interim and final reclamation actions for the Weaver Ridge 23-7H well pad that would need to occur to realize the objectives stated above. For more details please refer to the proposed BMP's on the attachment Tab.