TypeSource DocumentConditions of Approval
EngineerForm: (02 )
400239671
1/12/2012
1)COMPLIANCE WITH THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY IS REQUIRED. 2)THE PROPOSED SURFACE CASING IS MORE THAN 50' BELOW THE DEPTH OF THE DEEPEST WATER WELL WITHIN 1MILE OF THE SURFACE LOCATION WHEN CORRECTED FOR ELEVATION DIFFERENCES. THE DEEPEST WATER WELL WITHIN 1 MILE IS 000 FEET DEEP.
EngineerForm: (02 )
400239671
4/3/2012
1) BEFORE STIMULATING WELL, CAPTURE WATER SAMPLE FROM THOSE FORMATION(S) REQUESTED FOR INJECTION AND ANALYZE FOR TOTAL DISSOLVED SOLIDS. SUBMIT LAB ANALYSIS TO DENISE ONYSKIW AT DENISE.ONYSKIW@STATE.CO.US. 2) INJECTION IS NOT AUTHORIZED UNTIL APPROVAL OF FORM 31 AND 33. 3) A STEP RATE TEST TO DETERMINE FRACTURE PRESSURE IS PERMISSABLE BEFORE APPROVING FORMS 31 AND 33. The test volume must not exceed 5000 bbls and the test duration must not exceed 5 days or the test volume must not exceed 10,000 bbls and the test duration must not exceed 10 days.
AgencyForm: (05A )
400409738
9/24/2013
Wellbore diagram is doc 400393846, attached to Form 5 400393829.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Site SpecificForm: (02 )
400239671
4/5/2012
TWO WELL ARE PLANNED FOR THIS WELL SITE..
Drilling/Completion OperationsForm: (02 )
400239671
4/5/2012
CLOSED LOOP DRILLING SYSTEM.
ConstructionForm: (02 )
400239671
4/5/2012
UTILIZE EXISTING LEASE ROADS TO MINIMIZZE ANY NEW SURFACE DISTURBANCE. TOPSOIL WILL BE SEGREGATED AND STORED FOR RECLAMATION AT A LATER DATE
Material Handling and Spill PreventionForm: (02 )
400239671
4/5/2012
CHEVRON HAS AN ANNUALLY UPDATED ENFINEER CERTIFIED FULL FIELD SPCC PLAN IN ACCORDANCE WITH THE FEDERAL REQUIREMENT.