Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-11913EMERALD
97X
SCOUT ENERGY MANAGEMENT LLC
10779
PR
4/1/2024
RANGELY
72370
RIO BLANCO  103
SWNE 26 2N103W 6
428384View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02 )
400238886
1/12/2012
1)COMPLIANCE WITH THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY IS REQUIRED. 2)THE PROPOSED SURFACE CASING IS MORE THAN 50' BELOW THE DEPTH OF THE DEEPEST WATER WELL WITHIN 1MILE OF THE SURFACE LOCATION WHEN CORRECTED FOR ELEVATION DIFFERENCES. THE DEEPEST WATER WELL WITHIN 1 MILE IS 000 FEET DEEP.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Drilling/Completion OperationsForm: (02 )
400238886
3/30/2012
CLOSED LOOP DRILLING SYSTEM
Storm Water/Erosion ControlForm: (02 )
400238886
3/30/2012
STORM WATER PLANS AND EROSION CONTROL METHODS WILL BE USED TO ENSURE SITE STABILIZATION AND TO ENSURE ADEQUATE ENVIRONMENTAL SAFEGUARDS ARE IN PLACE TO PREVENT ANY STORM WATER RUNOFF. INSPECTION WILL BE DOCUMENTED AND FILED IN THE RANGELY FIELD OFFICE. THE CHEVRON RANGELY FIELD HAS A ANNUALLY REVIEWED FIELD WIDE STORMWATER MANAGEMENT PLAN.
General HousekeepingForm: (02 )
400238886
3/30/2012
THE WELL SITE WILL BE MAINTAINED IN A SANITARY CONDITION AT ALL TIMES AND ALL WASTE MATERIALS SHALL BE DIPOSED OF PROMPTLY AT APPROPRIATE WASTE DISPOSAL SITES.
ConstructionForm: (02 )
400238886
3/30/2012
CHEVRON WILL EMPLOY DUST SUPPRESSION TECHNIQUES OF FRESH WATER. UTILIZE EXISTING LEASE ROADS TO MINIMIZE ANY NEW SURFACE DISTURBANCE. ALL NEW ACCESS ROADS WILL BE CROWNED AND DITCHED ACCORDING TO BLM MANUAL SECTION 9113. THE TOPSOIL WILL BE SEGREGATED AND STORED SEPARATELY FOR THE SUBSURFACE MATERAILS.
WildlifeForm: (02 )
400238886
3/30/2012
POWERLINE DESIGN TO MINIMIZE RAPTOR ELECTROCUTION RISK. THERE WILL BE NO NEW SURFACE WORK FROM APRIL 15-TO JULY 15 TO ALLOW FOR PRAIRIE DOG REPRODUCTIVE PERIOD.
Material Handling and Spill PreventionForm: (02 )
400238886
3/30/2012
ALL FLUIDS WILL BE STORED IN APPROPRIATE CONTAINERS AND IN SECONDARY CONTAINMENT SYSTEMS ENGINEERED TO CONTAIN 150 PERCENT OF THE LARGEST VESSEL VOLUME. CHEVRON HAS AN ANNUALLY UPDATED ENGINEER CERTIFIED FULL FIELD SPCC PLAN IN ACCORDANCE WITH THE FEDERAL REQUIREMENTS OF 40 CFR PART 112
Site SpecificForm: (02 )
400238886
3/30/2012
TWO WELLS ARE PLANNED FOR THIS WELL SITE. THIS SITE IS LOCATED OFF EXISTING LEASE ROADS. THIS WELL SITE IS A LEVEL AREA TO MINIMIZE DIRT WORK. THIS WELL SITE IS NOT IN ANY RIPARIAN AREA, FLOODPLAIN, AND IS NOT SUBJECT TO EROSION. IT IS NOT A VISUALLY SENSITIVE AREA.