WELL05-103-10733PICEANCE CREEK UNIT
297-10A3
CAERUS PICEANCE LLC
10456
PR
4/1/2024
PICEANCE CREEK
68800
RIO BLANCO  103
SESE 10 2S97W 6
335696View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
AgencyForm: (02 )
1990348
5/29/2009
24 HOUR SPUD NOTICE REQUIRED. E-MAIL; JAIME.ADKINS@STATE.CO.US CEMENT TOP VERIFICATION BY CBL REQUIRED. THE PROPOSED SURFACE CASING IS MORE THAN 50' BELOW THE DEPTH OF THE DEEPEST WATER WELL WITHIN 1 MILE OF THE SURFACE LOCATION WHEN CORRECTED FOR ELEVATION DIFFERENCES. THE DEEPEST WATER WELL WITHIN 1 MILE IS _000_ FEET DEEP.
EngineerForm: (04 )
402016131
4/22/2019
Submit Form(s) 5/5A at completion of this procedure.
EngineerForm: (04 )
403180087
10/17/2022
1) Operator shall comply with COGCC Rule 419. Bradenhead Monitoring, Testing, and Reporting and Rule 420. Form 17, Bradenhead Test Report 2) At least once a year shut in bradenhead for 7 days or until the pressure reaches the bradenhead threshold and perform a bradenhead test. Report results on a Form 17, as specified in Rule 420 or other Director approved submittal method. 3) Within 30 days of completing the work, submit a Form 4 Subsequent Report - Bradenhead Plan
 
COGIS - Best Management Practice Results