Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08041EMERALD
63X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
8/1/2022
RANGELY
72370
RIO BLANCO  103
NWSE 25 2N103W 6
315184View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02 )
400300003
7/23/2012
1) COMPLY WITH RECENTLY UPDATED NW COLORADO NOTIFICATION PROCEDURES 2) PRIOR TO DRILLING SIDETRACK CONDUCT AN MIT ON THE 7” CASING AND PERFORM REMEDIAL WORK IF TEST FAILS 3) RUN CBL ON BOTH THE 5" AND 5 1/2" CASINGS FROM TD TO SURFACE 4) APPROVAL OF THIS FORM IS NOT APPROVAL TO INJECT. APPROVAL OF FORM 33 IS REQUIRED FOR INJECTION. 5) IMPLEMENT PUBLIC SAFETY PLAN IF RADIUS OF EXPOSURE IS EQUAL TO OR GREATER THAN 50' 6) READ AND FOLLOW COGCC POLICY FOR REPORTING HYDROGEN SULFIDE-SEE COGCC WEBSITE-MENU-POLICIES-REPORTING HYDROGEN SULFIDE
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Material Handling and Spill PreventionForm: (02 )
400300003
7/31/2012
LOCATION IS PART OF RANGELY FIELD WIDE SPCC PLAN
Storm Water/Erosion ControlForm: (02 )
400300003
7/31/2012
LOCATION IS PART OF RANGELY FIELD WIDE STORM WATER CONTROL PLAN, INSPECTED FOR EROSION MONTHLY.
Site SpecificForm: (02 )
400300003
7/31/2012
UTILIZING EXISTING WELL SITE AND WELLBORE