TypeSource DocumentConditions of Approval
EngineerForm: (02)
400473972
09/10/2013
1) Provide remedial cement from 250’ to at least 50’ above surface casing shoe (due to WW Permit #0041777, 160’ deep, located SWSW13-1N-58W). 2. Perform and submit a passing MIT.
EngineerForm: (04)
400474020
09/10/2013
1) Provide remedial cement from 250’ to at least 50’ above surface casing shoe (due to WW Permit #0041777, 160’ deep, located SWSW13-1N-58W).
EngineerForm: (04)
401348745
12/18/2017
1) Run CBL to determine top of cement. Cement must be 200' above J-Sand. 2) Provide remedial cement from 250’ to at least 50’ above surface casing shoe (due to WW Permit #0041777, 160’ deep, located SWSW13-1N-58W). Confirm with CBL and submit Form 5 updating well configuration. 3) Perform and submit a passing MIT before producing. The MIT should also be done within 30 days since the well is in TA status.
 