Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-077-10205WhF
DHS5C-20 D17998
LARAMIE ENERGY LLC
10433
PR
12/9/2019
PICEANCE HORIZONTAL MANCOS
68808
MESA  077
NWNW 17 9S98W 6
429734View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
400289147
06/25/2012
THE PROPOSED SURFACE CASING IS MORE THAN 50' BELOW THE DEPTH OF THE DEEPEST WATER WELL WITHIN 1MILE OF THE SURFACE LOCATION WHEN CORRECTED FOR ELEVATION DIFFERENCES. THE DEEPEST WATER WELL WITHIN 1 MILE IS 000 FEET DEEP. RUN CBL ON 7 5/8 INTERMEDIATE CASING FROM TD TO SURF CSG SHOE (1000’ DEPTH MINIMUM) RUN CBL ON 4 ½ PRODUCTION CASING FROM TD TO INTERMEDIATE CSG SHOE (5000’ DEPTH MINIMUM) ADHERENCE(S) TO THE FOLLOWING NOTICE TO OPERATORS APPLIES: NW AREA NOTIFICATION PROCEDURES
EngineerForm: (02)
400633664
07/02/2014
1) COMPLIANCE WITH THE MOST CURRENT REVISION OF THE NORTHWEST COLORADO NOTIFICATION POLICY IS REQUIRED. SEE ATTACHED NOTICE. 2) PROVIDE CEMENT COVERAGE FROM THE INTERMEDIATE CASING SHOE (7 5/8" 1ST STRING) TO A MINIMUM OF 200' ABOVE TOP OF GAS. VERIFY CEMENT WITH A CEMENT BOND LOG. 3) Operator acknowledges the proximity of the listed well. Operator agrees to provide mitigation option 2 (per the Interim Statewide Horizontal Offset Policy) to mitigate the situation, ensure all applicable documentation is submitted based on the selected mitigation option chosen, and submit a Form 42 (“OFFSET MITIGATION COMPLETED”) stating that appropriate mitigation occurred and that it has been completed, prior to the hydraulic stimulation of this well. USA 1-17JC (API#077-08314)
PermitForm: (02)
400633664
08/06/2014
Open hole resistivity and gamma logs shall be run to describe the stratigraphy of the entire well bore and to adequately verify the setting depth of surface casing and aquifer coverage. On a multi-well pad, these open hole logs are only required on one of the first wells drilled on the pad and the Drilling Completion Report - Form 5 for every well on the pad shall identify which well was logged.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
WildlifeForm: (02 )
400289147
7/27/2012
• Prohibit Encana employees and contractors from carrying projectile weapons on Encana leases. • Prohibit pets on Encana leases. • Strategically apply fugitive dust control measures, including enforcing established speed limits on Encana private roads, to reduce fugitive dust and coating of vegetation and deposition in water sources.
ConstructionForm: (02 )
400289147
7/27/2012
• Use solar panels as an alternative energy source for on-location production equipment, where appropriate, economically and technically feasible. • Use multiple gathering lines placed in a single trench to minimize disturbance and construction, where appropriate, economically and technically feasible. • Install pipeline crossings at right angles to the drainages, wetlands, and perennial water bodies, where appropriate, economically and technically feasible.