COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
401144684
02/08/2017
1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) Properly abandon flowlines per Rule 1103. File electronic Form 42 when flowline abandonment is complete. 3) Check the 8 5/8" x 5 1/2” (bradenhead) annulus pressure and report pressure on Form 6 Subsequent Report of Abandonment. Notify COGCC engineering staff if bradenhead gas or liquid flow is observed prior to perforating below the surface casing shoe.
 
COGIS - Best Management Practice Results