WELL05-073-06610BLACKCOMB
12-14
POLARIS PRODUCTION OPCO LLC
10793
SI
3/1/2022
ARIKAREE CREEK
2914
LINCOLN  073
NWSW 14 6S54W 6
437317View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
400563617
03/05/2014
1) Provide 48 hour notice prior to spud via electronic Form 42. 2) Provide cement coverage to 200’ above shallowest completed interval or 200’ above SPGN, whichever is deeper, and stage cement Cheyenne/Dakota interval (5100’ – 4450’). Verify w/ CBL. 3) If well is a dry hole set the following plugs: 40 sks cement +/- 50’ above the SPGN, 40 sks cement across any DST w/ show, 40 sks cement 100’ below base of Cheyenne (5100’ up), 40 sks cement 100’ above top of Dakota (4450’ up), 50 sks cement from 50’ below surface casing shoe up into surface casing, 15 sks cement in top of surface csg, cut 4 ft below GL, weld on plate, 5 sks cement each in rat hole and mouse hole.
PermitForm: (02)
400563617
04/22/2014
Open hole resistivity and gamma logs shall be run to describe the stratigraphy of the entire well bore and to adequately verify the setting depth of surface casing and aquifer coverage. On a multi-well pad, these open hole logs are only required on one of the first wells drilled on the pad and the Drilling Completion Report - Form 5 for every well on the pad shall identify which well was logged.
EnvironmentalForm: (04)
400615491
05/29/2014
A review of DWR data on the COGCC website indicates that there are no water features that meet the 100 series definition of a water source within ½ mile of the oil and gas well(s).
EngineerForm: (04)
400718762
01/22/2015
1) The flaring of natural gas shall be conducted in accordance with COGCC Rule 912 for the initial production test period. 2) Notify the local emergency dispatch or the local governmental designee of any natural gas flaring. 3) If flaring will continue more than 6 months, submit updated requests to flare to COGCC on Form 4 (Sundry Notice), which discusses timing to connect to sales line, plans to develop infrastructure, and justification for continued venting/flaring. 4) The operator is required to obtain and maintain any required air permits from CDPHE. 5) The venting or flaring volumes shall be reported by Form 7, Operator’s Monthly Report of Operations.
EngineerForm: (04)
400981978
03/03/2016
1) Submit requests to flare annually to COGCC on Form 4 (Sundry Notice), which discusses timing to connect to sales line, plans to develop infrastructure, and justification for continued venting/flaring. Provide gas analysis including H2S with each Sundry Notice. 2) Venting or flaring of natural gas shall comply with COGCC Rule 912. 3) Report flaring volumes on Form 7, Operator’s Monthly Report of Operations. 4) Notify the local emergency dispatch or the local governmental designee of natural gas flaring. 5) The operator is required to obtain and maintain any required air permits from CDPHE. The combustion device must comply with applicable design destruction efficiency for hydrocarbons.
UICForm: (02)
401135870
10/24/2016
Injection is not authorized until approval of Subsequent Forms 31 and 33.
UICForm: (02)
401135870
10/24/2016
Operator required to file Form 4 Sundry Notice with all formation tops from surface to at least top of Niobrara as shown on Scout Card.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
ConstructionForm: (02 )
400563617
5/25/2014
Certificate to Discharge Under CDPHE General Permit No. COR-030000 Stormwater Discharges Associated with Construction Certification No. COR031825 Prior to construction, perimeter controls will be installed utilizing cuttings from the clearing operations. Once the well pad has been constructed a variety of BMP's shall be utilized for the site specific conditions. BMP's to be utilized may include, but are not limited to: -Dirt/Ditch Berm -Erosion Control Blankets -Starw Bale Barrier -Straw Wattles -Seeding -Imported Hard Armor -Check Dams -Culvert/Culvert Protection -Crimped Straw -Silt Fence -Surface Roughtening/Surface Rip During construction, each site will be inspected every 14 days and 24-72 hours after any precipitation event causing erosion depending on the current site activities. These inspections will be recorded and maintained at Nighthawk's office. Repairs shall be completed as soon as possible after an inspection reporting BMP repairs are required. Any site specific modifications will be revised on the site plan when implemented at the site. A field wide Stormwater Management Plan (SWMP) for the Porject Area are stored on file at Nighthawk's office. Spill Control and Countermeasures (SPCC) plans for the Project Area are stored on file at Nighthawk's office. The field wide SWMP addressess SPCC during construction operations.
Storm Water/Erosion ControlForm: (02 )
401135870
11/27/2016
Plan in place - Under Jolly Ranch Project Area