| Engineer | Form: (02) 400378458 03/11/2013 | 1) Provide 48 hour notice prior to spud via electronic Form 42.
2) If production casing is set provide cement coverage to at least 200’ above the shallowest completed interval or Spergen, whichever is shallower and across Cheyenne/Dakota interval (up to 4500’ min). Run and submit CBL verify cemented intervals.
3) If well is a dry hole set plugs at the following depths: 40 sks cement +/- 50’ above the Spergen, 40 sks cement across any DST w/ show, 40 sks cement 100’ below Cheyenne, 40 sks cement 50’ above top of Dakota (4500’ up), 50 sks cement from 50’ below surface casing shoe up into surface casing, 15 sks cement in top of surface casing, cut 4 ft below GL, weld on plate, 5 sks cement each in rat hole and mouse hole.
|
| Engineer | Form: (02) 400410792 05/01/2013 | 1) If production casing is set provide cement coverage to at least 200’ above the shallowest completed interval or
Spergen, whichever is shallower and across Cheyenne/Dakota interval (up to 4500’ min). Run and submit CBL verify
cemented intervals.
2) If well is a dry hole set plugs at the following depths: 40 sks cement +/- 50’ above the Spergen, 40 sks cement across any DST w/ show, 40 sks cement 100’ below Cheyenne, 40 sks cement 50’ above top of Dakota (4500’ up), 50 sks cement from 50’ below surface casing shoe up into surface casing, 15 sks cement in top of surface casing, cut 4 ft below
GL, weld on plate, 5 sks cement each in rat hole and mouse hole. |
| Engineer | Form: (04) 400692246 10/14/2014 | 1) The flaring of natural gas shall be conducted in accordance with COGCC Rule 912.
2) Notify the local emergency dispatch or the local governmental designee of any natural gas flaring.
3) If flaring will continue more than 6 months, submit updated requests to flare to COGCC on Form 4 (Sundry Notice), which discusses timing to connect to sales line, plans to develop infrastructure, and justification for continued venting/flaring.
4) The operator is required to obtain and maintain any required air permits from CDPHE.
5) The venting or flaring volumes shall be reported by Form 7, Operator’s Monthly Report of Operations.
|
| Engineer | Form: (04) 400980092 03/02/2016 | 1) Venting or flaring of natural gas shall comply with COGCC Rule 912.
2) Submit requests to flare annually to COGCC on Form 4 (Sundry Notice), which discusses timing to connect to sales line, plans to develop infrastructure, and justification for continued venting/flaring. Provide gas analysis including H2S with each Sundry Notice.
3) Report flaring volumes on Form 7, Operator’s Monthly Report of Operations.
4) The operator is required to obtain and maintain any required air permits from CDPHE. The combustion device must comply with applicable design destruction efficiency for hydrocarbons (typically enclosed device 98%).
5) Notify the local emergency dispatch or the local governmental designee of natural gas flaring.
|
| Engineer | Form: (04) 401215385 04/26/2017 | 1) Venting or flaring of natural gas shall comply with COGCC Rule 912.
2) Submit requests to flare annually to COGCC on Form 4 (Sundry Notice), which discusses timing to connect to sales line, plans to develop infrastructure, and justification for continued venting/flaring. Provide gas analysis including H2S with each Sundry Notice.
3) Report flaring volumes on Form 7, Operator’s Monthly Report of Operations.
4) The operator is required to obtain and maintain any required air permits from CDPHE. The combustion device must comply with applicable design destruction efficiency for hydrocarbons (typically enclosed device 98%).
|
| Engineer | Form: (04) 401521859 12/06/2018 | This approval is good for one year and new application must be made before February 1, 2019. |
| Engineer | Form: (04) 401521859 12/06/2018 | Presence of hydrogen sulfide should be reported on a Form 42, Field Operations Notice. |
| Engineer | Form: (04) 401521859 12/06/2018 | 1) Flaring of natural gas shall comply with COGCC Rule 912.
2) Submit requests to flare annually to COGCC on Form 4 (Sundry Notice), which discusses timing to connect to sales line, plans to develop infrastructure, and justification for continued venting/flaring. Provide gas analysis including H2S with each Sundry Notice.
3) Report metered flaring volumes on Form 7, Operator’s Monthly Report of Operations.
4) The operator is required to obtain and maintain any required air permits from CDPHE.
5) The expectation for permanent flares controlling separators will be an enclosed combustion device with a 98% design destruction efficiency for hydrocarbons.
6) Notify the local emergency dispatch or the local governmental designee of natural gas flaring.
|
| Engineer | Form: (04) 402159355 12/19/2019 | 1) Flaring of natural gas shall comply with COGCC Rule 912.
2) Submit requests to flare annually to COGCC on Form 4 (Sundry Notice), which discusses timing to connect to sales line, plans to develop infrastructure, and justification for continued venting/flaring. Provide gas analysis including H2S with each Sundry Notice.
3) Report metered flaring volumes on Form 7, Operator’s Monthly Report of Operations.
4) The operator is required to obtain and maintain any required air permits from CDPHE.
5) The expectation for permanent flares controlling separators will be an enclosed combustion device with a 98% design destruction efficiency for hydrocarbons.
6) Notify the local emergency dispatch or the local governmental designee of natural gas flaring.
This approval is good for one year and new application must be made before 1/31/20.
|