| Agency | Form: (02) 1783878 07/24/2009 | <style type="text/css">
p {margin:0px 0px 0px 2px;}
ul {margin-top:2px;margin-bottom:2px;}
ol {margin-top:2px;margin-bottom:2px;}
H1 {font-family:Arial;font-size:28px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;}
H2 {font-family:Arial;font-size:24px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;}
H3 {font-family:Arial;font-size:18px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;}
.Normal {font-family:Arial;font-size:14px;text-align:Left;vertical-align:Middle;color:#000000;}
.TableDefault {border-collapse:collapse;border:1px solid #000000;}
.TableDefault th {padding:2px;vertical-align:top;text-align:left;border:1px solid #000000;}
.TableDefault td {padding:2px;vertical-align:top;text-align:left;border:1px solid #000000;}
</style>
<p><span class="Normal">1) Provide 24 hour notice of MIRU to Mike Leonard at 719-767-2805 or e-mail at mike.leonard@ state.co.us. </span><span class="Normal">2) If production casing is set provide cement coverage to at least 200’ above Lansing, and stage cement </span><span class="Normal">Cheyenne & Dakota (4620’-4060’ minimum). Run CBL to verify primary and stage cement jobs. 3) If well is a </span><span class="Normal">dry hole set plugs at the following depths: 40 sks cement +/- 50’ above the Lansing, 40 sks cement above any </span><span class="Normal">DST zone, 40 sks cement 100’ below base of Cheyenne (4620’ up), 40 sks cement 50’ above top of Dakota </span><span class="Normal">(4060’ up), 50 sks cement from 50’ below surface casing shoe up into surface casing, 10 sks cement in top of </span><span class="Normal">surface casing, cut 4 ft below GL, weld on plate, 5 sks cement in rat hole and mouse hole.</span></p>
|
| Agency | Form: (02) 1783878 07/29/2009 | <style type="text/css">
p {margin:0px 0px 0px 2px;}
ul {margin-top:2px;margin-bottom:2px;}
ol {margin-top:2px;margin-bottom:2px;}
H1 {font-family:Arial;font-size:28px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;}
H2 {font-family:Arial;font-size:24px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;}
H3 {font-family:Arial;font-size:18px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;}
.Normal {font-family:Arial;font-size:14px;text-align:Left;vertical-align:Middle;color:#000000;}
.TableDefault {border-collapse:collapse;border:1px solid #000000;}
.TableDefault th {padding:2px;vertical-align:top;text-align:left;border:1px solid #000000;}
.TableDefault td {padding:2px;vertical-align:top;text-align:left;border:1px solid #000000;}
</style>
<p><span class="Normal">SEE ATTACHED NOTICE CONCERNING OPERATING REQUIREMENTS FOR WILDLIFE PROTECTION </span></p>
|
| Engineer | Form: (02) 400536458 01/13/2014 | 1) Provide 48 hour notice prior to spud via electronic Form 42.
2) If production casing is set provide cement coverage to at least 200’ above the
Lansing and cement across Cheyenne/Dakota interval: (4640’-4080’ minimum). Run
and submit CBL to verify cemented intervals.
3) If well is a dry hole set plugs at the following depths: 40 sks cement +/- 50’ above the
Osage, 40 sks cement +/- 50’ above the Morrow, 40 sks cement +/- 50’ above the
Cherokee, 40 sks cement +/- 50’ above the Lansing, 40 sks cement +/- 50’ above any
DST w/ show, 40 sks cement at 4690’ up, 40 sks cement at 4080’ up, 50 sks cement
from 50’ below surface casing shoe up into surface casing, 15 sks cement in top of
surface casing, cut 4 ft below GL, weld on plate, 5 sks cement each in rat hole and
mouse hole. |
| Permit | Form: (02) 400536458 02/11/2014 | Open hole resistivity and gamma logs shall be run to describe the stratigraphy of the entire well bore and to adequately verify the setting depth of surface casing and aquifer coverage. On a multi-well pad, these open hole logs are only required on one of the first wells drilled on the pad and the Drilling Completion Report - Form 5 for every well on the pad shall identify which well was logged. |
| Permit | Form: (02) 400536458 02/11/2014 | Operator shall comply with Buffer Zone Move-In, Rig-Up Notice Policy dated 12-16-2013. |