Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-067-09023IGE
401
ELM RIDGE EXPLORATION COMPANY LLC
26625
PA
11/3/2014
IGNACIO BLANCO
38300
LA PLATA  067
NWNW 17 33N8W N
311909View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06)
400587256
06/11/2014
1) Notify COGCC regional engineer 48 hrs prior to MIRU at mark.weems@state.co.us or 970-259-4587. 2) Purge the flow lines, cut off 3’-4’ deep, and cap. Remember to note on form 6, page two under the Additional Plugging Information for Subsequent Report Only. (COGCC Rule 1103) 3) Prior to killing the well, measure the surface casing pressure (Braden Head) and then blow it down. Continue to monitor the surface casing pressure throughout the PA. 4) Leave a vent hole in casing/marker to avoid trapping any residual pressure in the casing(s)
 
COGIS - Best Management Practice Results
No records to display.