TypeSource DocumentConditions of Approval
EngineerForm: (04)
403215457
11/04/2022
1) Provide electronic Form 42 Notice of MIRU 2 business days ahead of operations. 2) Report work completed with a Form 4 Sundry SUBSEQUENT REPORT – Repair Well; noting final pressure test results no later than December 31, 2022. 3) If a casing leak is identified, contact the area engineer with repair plans. 4) If wellbore geometry changes or cement work is executed, submit information on a Form 5.
EngineerForm: (04)
403326429
02/28/2023
1) Operator will implement measures to control venting, to protect health and safety, and to ensure that vapors and odors from well operations do not constitute a nuisance or hazard to public welfare. 2) During the shut-in period record pressure data to adequately characterize the buildup. 3) A Form 4, Sundry Notice will be submitted no later than May 21, 2023, to provide an update of the current well pressures and a summary of work completed.
EngineerForm: (04)
403373644
04/17/2023
1) Operator will implement measures to control venting, to protect health and safety, and to ensure that vapors and odors from well operations do not constitute a nuisance or hazard to public welfare. 2) During the shut-in period record pressure data to adequately characterize the buildup. 3) A Form 4, Sundry Notice will be submitted no later than May 28, 2023 to provide an update of the current well pressures and a summary or work completed.
EngineerForm: (04)
403411659
06/20/2023
This well may be returned to annual testing and monthly monitoring. If at any point in the future bradenhead conditions exceed thresholds a new bradenhead mitigation sundry must be filed.
EngineerForm: (04)
404066021
01/28/2025
1) Provide electronic Form 42 Notice of MIRU 2 business days ahead of operations for repair work. 2) Operator shall implement measures to control venting, to protect health and safety, and to ensure that vapors and odors from well operations do not constitute a nuisance or hazard to public welfare. 3) If a casing leak is identified, contact the Area Engineer with repair plans. A CBL needs to be run as indicated depth, to verify existing cement coverage. 4) All repair work and a successful MIT (if needed) shall be completed by 6/30/2025. 5) At the end of repair and diagnosis (06/30/2025), conduct a new bradenhead test and submit the Form 17 within ten days of the test and submit a Form 4 Sundry that summarizes current well condition. The sundry should include details of the future plans, and all logs run. Shut in bradenhead pressure shall not exceed 25 psig.
EngineerForm: (04)
404242563
06/23/2025
Operator shall continue to monitor pressure and report to ECMC through annual testing. If monitored well conditions meet reaction threshold or indicate a deficiency, a new bradenhead test and sundry must be filed.
 