WELL05-057-06605Janet 0780
4-16H21
FULCRUM ENERGY OPERATING LLC
10805
PR
4/1/2025
NORTH PARK HORIZONTAL NIOBRARA
60120
JACKSON  057
NWNW 16 7N80W 6
439603View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
401331637
09/18/2017
1)Operator shall comply with the most current revision of the Northwest Notification Policy. 2) Operator shall provide cement coverage from the production casing shoe (5 1/2" First String) to a minimum of 200' above the surface casing shoe to provide full isolation of the Coalmont Formation. Verify production casing cement coverage with a cement bond log.
EngineerForm: (04)
401746234
02/22/2019
1) Comply with all requirements of Rule 912, including monthly reporting of flared volumes (on Form 7) and notifications to local emergency dispatch or the local government designee. 2) Submit annual updates (requests to flare) to COGCC on Form 4s (Sundry Notices), including all information specified in COGCC’s "Notice to Operators, Rule 912 Venting or Flaring Produced Natural Gas - Statewide." 3) Comply with any Colorado Department of Public Health and Environment, Air Pollution Control Division rules or requirements for all atmospheric discharges. 4) An enclosed flare shall be used, unless an open flare is specifically allowed by CDPHE’s Regulation 7. 5) With the next annual update (request to flare), collect a new gas sample for laboratory analysis including hydrogen sulfide and submit a Form 43 to upload the laboratory results to the COGCC Environmental Database. Form 43 instructions are on COGCC’s website under Regulation => Forms => Form 43 COGCC Environmental Database.
EngineerForm: (04)
402292912
02/12/2020
1) Comply with all requirements of Rule 912, including monthly reporting of flared volumes (on Form 7) and notifications to local emergency dispatch or the local government designee. 2) Submit annual updates (requests to flare) to COGCC on Form 4s (Sundry Notices), including all information specified in COGCC’s "Notice to Operators, Rule 912 Venting or Flaring Produced Natural Gas - Statewide." Next sundry request due 1/23/2021. 3) Comply with any Colorado Department of Public Health and Environment, Air Pollution Control Division rules or requirements for all atmospheric discharges. 4) An enclosed flare shall be used, unless an open flare is specifically allowed by CDPHE’s Regulation 7. 5) With the next annual update (request to flare), collect a new gas sample for laboratory analysis including hydrogen sulfide and submit a Form 43 to upload the laboratory results to the COGCC Environmental Database. Form 43 instructions are on COGCC’s website
EngineerForm: (04)
402522961
01/27/2021
Following the anticipated acquisition of certain assets owned and operated by SandRidge Energy in Jackson County, Colorado, SandRidge acknowledges Gondola Resources plans to modify SandRidge’s pending Gas Capture Plan for the JANET 0780 4-16H21 well and the eight additional wells on the Gregory Pad. Gondola will install one JT Unit on the pad and one Arrow 90T genset for each well on the pad and use natural gas from the wells to power the engines on the pad. This work is expected to commence in the Spring of 2021 and conclude in the Summer of 2021. In addition, Gondola will engage an established third party to utilize and route remaining field gas from the Gregory Pad to power a mobile data center and energy intensive computing facilities located on the Big Horn Pad. Gondola anticipates this arrangement to be deployed and operational by year end.
EngineerForm: (04)
402522961
01/29/2021
1) Flaring of natural gas shall comply with COGCC Rule 903. 2) Report metered volumes on Form 7, Operator’s Monthly Report of Operations for gas flared, sold or used on location. 3) The operator is required to obtain and maintain any required air permits from CDPHE. 4) The expectation for permanent flares controlling separators or residual gas will be an enclosed combustion device with a 98% design destruction efficiency for hydrocarbons. Operator shall manage this well so that production volumes do not exceed the combustor capacity. 5) Operator is to provide prior notification to the local emergency dispatch or the local governmental designee of any flaring or venting event. Operator shall have an approved Gas Capture Plan or have sought and received a variance from the COGCC Commission for continued production without gas infrastructure, prior to January 15, 2022 or wells must be shut in by January 15, 2022.
EnvironmentalForm: (04)
402891264
12/10/2021
Because the Form 9 -Transfer of Ownership has not been approved by COGCC Staff, the operator’s Form 43(s) for this well will be due 30 days from the date the Form 9 is approved.
EngineerForm: (04)
403009017
03/30/2023
Resubmitted Bradenhead test results, 5/9/22 - SCP=20 down to 0 psi, water, samples=none 12/15/22 - SCP=2 down to 0 psi, gas, samples=none Submit sundry as specified in plan contained herein, to have been submitted following 6 month period ending 12/1/22, with the results of monthly blow downs, volume estimates and sample analysis. Repeat the Bradenhead test by 6/1/23 and submit results of test and future plans by 7/1/2023.
EngineerForm: (04)
403455823
07/12/2023
Wells that flow liquids during the bradenhead test are not eligible for the test data bulk upload. A Form 17 is required 10 days after the test and shall be filed by 7/21/2023.
EngineerForm: (04)
403455823
07/12/2023
The attached data indicates that the bradenhead continues to flow liquid each time the surface casing is checked, Continue with monthly blowdowns and submit results in 6 months, 1/6/24. Include casing starting and ending pressure, a graph of the build-up and blowdown, volume and be prepared to take samples if required.
EngineerForm: (04)
403645004
01/17/2024
Approval of this sundry extends the due date for the 1/2024 bradenhead test and subsequent Form 17 submittal to 4/30/2024. Please summarize the test results and include action items in the operator comments box on the sundry. Attachments should support the summary submitted in the comments.
EngineerForm: (04)
403879390
02/03/2025
1) Monitor monthly and record the wellhead pressure, blowdown volumes and fluid type produced. 2) Following a 7 day shut in period, perform a Bradenhead test by 4/15/2025 and submit a Form 17 in 10 days of the test. 3) Submit a Form 4 Sundry with pressure data and sample analysis interpretation for the previous 12 months, by 4/25/25. Include a proposed plan for the continuing mitigation on this well. Be prepared to implement mitigation plans as soon as weather permits.
EngineerForm: (04)
404086429
02/19/2025
1) Monitor monthly and record the wellhead pressure, blowdown volumes and fluid type produced. 2) Following a 7 day shut in period, perform a Bradenhead test by 4/15/2025 and submit a Form 17 in 10 days of the test. 3) Submit a Form 4 Sundry with pressure data and sample analysis interpretation for the previous 12 months, by 4/25/25. Include a proposed plan for the continuing mitigation on this well. Be prepared to implement mitigation plans as soon as weather permits.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Drilling/Completion OperationsForm: (02 )
401331637
9/26/2017
The first well on this pad, Gregory 0780 1-9H, API No. 05-057-06539, was logged with open-hole Resistivity Log and Gamma Ray Log from the kick-off point into the surface casing. All subsequent wells drilled on the pad will have a cement bond log with gamma-ray run on the production casing (or on intermediate casing if production liner is run) into the surface casing. The horizontal portion of every well will be logged with a measured-while-drilling gamma-ray log. The Form 5, Completion Report, for each well on the pad will list all logs run and have those logs attached. The Form 5 for wells without open-hole logs shall clearly state “No open-hole logs were run” and shall clearly identify Gregory 0780 1-9H, API No. 05-057-06539 in which open-hole logs were run.