WELL05-057-06565Evans 0780
8-21H
FULCRUM ENERGY OPERATING LLC
10805
SO
8/21/2016
WILDCAT
99999
JACKSON  057
SESW 16 7N80W 6
446527View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
401054549
06/22/2016
1)Operator shall comply with the most current revision of the Northwest Notification Policy. 2) Operator shall provide cement coverage from the production casing shoe (5+1/2" First String) to a minimum of 200' above the surface casing shoe to provide full isolation of the Coalmont Formation. Verify production casing cement coverage with a cement bond log.
EnvironmentalForm: (04)
401135695
11/23/2016
All stockpiled material shall have proper stormwater BMP’s, to prevent the migration of soil.
EnvironmentalForm: (04)
401135695
11/23/2016
The operator has informed COGCC that any stockpiled cuttings will be removed or in their final disposition by July 2017.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Drilling/Completion OperationsForm: (02 )
401054549
7/22/2016
One of the first wells drilled on the pad will be logged with open-hole Resistivity Log and Gamma Ray Log from the kick-off point into the surface casing. All wells on the pad will have a cement bond log with gamma-ray run on production casing (or on intermediate casing if production liner is run) into the surface casing. The horizontal portion of every well will be logged with a measured-while-drilling gamma-ray log. The Form 5, Completion Report, for each well on the pad will list all logs run and have those logs attached.The Form 5 for a well without open-hole logs shall clearly state “No open-hole logs were run” and shall clearly identify (by API#, well name & number) the well in which open-hole logs were run.